Fiber Optic MPO/MTP

Your Professional Fiber Optic MPO/MTP Supplier
 

Founded in 2017, Shenzhen Bray Communication Technology Co., Ltd. (BRAY-CT) is a professional manufacturer specializing in mold manufacturing, plastic injection molding, and product assembly services. Supported by a team with over 20 years of industry experience, we provide one-stop plastic product solutions for e-commerce brands, startups, and small to medium-sized enterprises worldwide. Our factory integrates R&D, tooling, injection molding production, and assembly under one roof to ensure efficient communication and stable quality control. Equipped with 29 injection molding machines and experienced engineering teams, we are capable of supporting both prototype development and mass production with reliable lead times and flexible manufacturing solutions for global customers.

 

 
  • Mtp Mpo Fiber Breakout Cable
    MPO/MTP fan-out patch cord, is a fiber optic cable terminated with MPO/MTP connectors on one end and MTP/MPO/LC/FC/SC/ST/MTRJ connectors(generally MTP to LC) on the other end. The main cable is...
    read more
  • Mtp Mpo Trunk Cable Assemblies
    MPO/MTP trunk cable assemblies facilitate rapid deployment of high density backbone cabling in data centers and other high fiber environment, reducing network in stallation or reconfiguration time...
    read more
  • Mpo Mtp Fiber Optic Patch Cord
    MTP/MPO patch cords are generally used to support parallel optical communications and are available as either 12 or 24 fibre configurations.
    read more
  • Mpo Mtp 12 Fiber Connectors
    The MPO/MTP patch cord is a multi-fiber jumpers which is used in high density fiber networks. It's specifically designed for fast ether net, data center, fiber channel and gigabit ether net...
    read more
 
Why choose us

One-Stop Manufacturing Solution

From mold development to injection molding, assembly, and packaging, we provide complete manufacturing solutions under one roof.

Our Certificate

Certified with ISO9001, we implement full-process quality inspection from raw materials to final delivery, ensuring consistent product quality and reliability.

Flexible Customization Support

Customers can provide concepts, sketches, 3D files, or physical samples. Our team offers technical evaluation and tailored manufacturing solutions based on different project needs.

Sales Market

Our products are mainly exported to Europe and Asia-Pacific markets, with annual sales exceeding RMB 30 million, demonstrating stable cooperation with overseas customers.

 

Mpo Mtp Fiber Optic Patch Cord

 

 

MTP/MPO patch cords are typically made of high-quality optical fiber enclosed in a protective jacket, with MTP/MPO connectors on both ends. MPO/MTP patch cords are the similar as LC/SC/FC and other fiber optic patch cords. The difference is the number of connectors and fiber cores. MPO connectors are more complex than LC/SC/FC connectors.

 

Specification

 

Connector A

MPO/MTP Female

Connector B

MPO/MTP Female

Fiber Mode

G652D, G.657A1, OM3, OM4 ,OM5 option

Wavelength

850/1310 nm

Typical Insertion Loss(Elite)

≤ 0.35 dB

Typical Insertion Loss

≤ 0.70 dB

Max Insertion Loss(Elite)

≤ 0.75 dB

Durability(500 Mating Times)

△IL≤ 0.75 dB

Cable Jacket

LSZH or PVC

Fiber Count

8,12,24 fiber

Cable Type

Round cable&Ribbon cable

Jacket OD

3.0mm&2.0mm*5.0mm

Operating Temperature

-40°C to 80°C

Storage Temperature

-40°C to 85°C

 

 
 
Advantages of Mpo Mtp Fiber Optic Patch Cord
mpo mtp trunk cable

Stability and Durability

The sleeve design of MTP connectors reduces the possibility of signal instability to some extent, enhancing durability.

 

mpo 12 转 lc 电缆

Time and Cost Savings, High Deployment Efficiency

The time required for MPO/MTP cabling is significantly reduced. Using pre-terminated cables for plug-and-play installation saves time and effort, and lowers maintenance costs in the long run.

c0.9mm LC fanout patch cord

High Density and Scalability

MTP connectors comply with telecommunications-grade Telcordia standards, addressing the challenge of carrying multiple fibers in a small capacity. For instance, while LC duplex connectors in a 1U chassis accommodate 144 fiber cores, MTP connectors can accommodate 864 fiber cores, nearly six times the capacity of the former.

mpo mtp fiber optic patch cord

Preparation for Network Upgrades

MTP cabling supports direct connections for 40G-40G, 100G-100G, 200G-200G, and 400G-400G, as well as upgrades and upstream connections. Upgrading from 10G to higher Ethernet speeds like 40G/100G/120G using MPO/MTP cabling systems is common and economically reliable.

 

Type of Mpo Mtp Fiber Optic Patch Cord
 

MTP/MPO Trunk Cable

MTP/MPO trunk cable is terminated with an MTP/MPO connector (female/male) on both ends, which is available in 8-144 fiber counts for users’ choices. Typically, MTP/MPO trunk cable is ideal for creating a structured cabling system, including backbone and horizontal interconnections such as 40G-40G and 100G-100G direct connections.

MTP/MPO Breakout Cable

MTP/MPO splitter cables (also known as harness cable or fan-out cables) are terminated with a female/male MTP/MPO connector on one end and a 4/6/8/12 duplex LC/FC/SC/ST connector on the other, such as 8-core MTP/MPO to 4 LC bundle cables and 12-core MTP/MPO to 6 LC bundle cables. Typically, MTP/MPO splitter cables are ideal for short 10G-40G and 25G-100G direct connections or for connecting backbone components to rack systems in high-density backbone cabling.

MTP/MPO Conversion Cable

MTP/MPO conversion cable has the same fanout design as MTP/MPO breakout cable but is different in fiber counts and types. MTP/MPO conversion cable is terminated with MTP/MPO connectors on both ends. MTP/MPO conversion cable is available in 24-fiber to 2×12-fiber, 24-fiber to 3×8-fiber, and 2×12-fiber to 3×8-fiber types, and is ideal for 10G-40G, 40G-40G, 40G-100G, and 40G-120G connections, which eliminate fiber wasting and largely increase the flexibility of the MTP/MPO cabling system.

 

Applications of Mpo Mtp Fiber Optic Patch Cord

 

 
 

Data Centers

Used for high-speed connections between switches, servers, and patch panels in 100G/400G/800G networks.

 
 

AI and HPC Clusters

Connect GPUs and AI systems with ultra-high-speed optical links for AI computing.

 
 

FTTH (Fiber to the Home)

Helps telecom operators deliver fiber internet to many homes more efficiently.

 
 

CATV and Video Systems

Used in cable TV and IPTV networks for stable, high-quality video signal transmission.

 
 

Storage Area Networks (SAN)

Connects storage devices and servers in enterprise data storage systems.

 
 

Telecom Backbone Networks

Supports long-distance, high-capacity optical communication between telecom centers.

 
 

Military and Aerospace

Used in harsh environments that require strong and reliable fiber connections.

 
 

Enterprise Campus Networks

Connects buildings and network rooms in universities, hospitals, and large companies.

 

Components of Mpo Mtp Fiber Optic Patch Cord
 

MT Ferrule

Holds and aligns multiple fibers accurately for connection.

Guide Pins

Metal pins that help connectors line up correctly and reduce signal loss.

Housing and Key

The outer shell protects the connector, while the key ensures correct connection direction.

Fiber Ribbon / Breakout

Fibers inside the cable can be arranged in a ribbon or split into individual connectors.

Spring Lock Mechanism

Keeps the connector securely connected during use.

Dust Caps and Pull Eyes

Dust caps protect the fiber endface, and pull eyes help with cable installation.

 

mtp mpo 主干电缆组件

 

How It Works of Mpo Mtp Fiber Optic Patch Cord

Step 1: Fiber Positioning: Each optical fiber is precision-inserted into the MT ferrule's micro-holes. The fibers are held in a fixed, parallel array with exact pitch spacing (typically 250 μm or 127 μm between adjacent fibers).

 

Step 2: Active Alignment via Guide Pins: When a male connector is pushed into a female adapter, the two guide pins enter the corresponding holes first. This mechanical action forces both ferrules into perfect axial and lateral alignment before the fiber endfaces make contact. This "active alignment" eliminates the need for manual adjustment.

 

Step 3: Optical Coupling: Once the ferrules are fully seated, the polished fiber endfaces (PC, UPC, or APC) are brought into close proximity or physical contact. Light signals pass from one fiber to the corresponding fiber in the mating connector with minimal loss. For UPC-polished multimode fibers, return loss exceeds 50 dB; for APC-polished single-mode fibers, it exceeds 60 dB.

 

How to Choose Mpo Mtp Fiber Optic Patch Cord
 
 
 

SR4 = 12 fibers (8 used)

QSFP-DD SR8 = 16 fibers (all used). QSFP56 = 8 fibers. SFP56 = 8 fibers.

 
 

Determine Connector Gender

Equipment ports are typically female (receptacle), so your patch cord end should be male (with pins). If connecting two patch cords via an adapter, one end must be male and the other female.

 
 

Determine Key Orientation and Polarity

Check your equipment documentation. Device-to-patch-panel = Type A (Key Up to Key Down). Switch-to-switch = Type B (Key Up to Key Up).

 
 

Determine Fiber Type and Polish

100G+ multimode = OM4 with UPC polish. Long-distance single-mode = OS2 with UPC or APC polish. CATV = single-mode APC.

 

 

Installation Precautions

Avoid removing dust caps from connectors before mating. If the connectors are connected to adapter panels but not yet mated, it is advisable to keep the dust caps in place.

 

Avoid contact or scraping of connector end faces with any other objects, except during regular mating.

 

If there is visible dirt or contamination on the end face, clean it using specialized cleaning tools or lint-free wipes soaked in anhydrous alcohol. Do not use tissues, cotton swabs, or ordinary cotton balls for end face cleaning.

 

When mating connectors, ensure proper alignment and avoid repeated insertions and removals without visual inspection of the end face.

 

When inserting MPO connectors into adapters, hold the connector by the boot. When removing them, hold the connector by the housing.


Maintain a minimum bending radius for the cable, which should be equal to or greater than 20 times the cable outer diameter.

 

When bundling cables, ensure appropriate tension to avoid excessive deformation of the cable jacket.

 

When routing cables through holes or conduits, use a pushing and pulling method instead of dragging or forcefully pushing the cable to prevent scraping or cable breakage.

 

 

FAQ

 

Q: Can you accept small order?

A: Yes, small order is available .We support new project of our customers as we know business is always from small order.

Q: What is your warranty period?

A: 25 years for fiber optic cable

Q: What is your delivery time?

A: Usually within 2-3 working days

Q: What is your payment way?

A: T/T, L/C, Western Union and Paypal.

Q: Can you supply customized products and logo?

A: Yes. We supply OEM&ODM service. You can send us your drawing.

As one of the most professional fiber optic mpo/mtp manufacturers and suppliers in China, we're featured by quality products and good service. Please rest assured to wholesale customized fiber optic mpo/mtp from our factory. For quotation, contact us now.

mpo fanout cable, mtp to lc adapter, 12 core fiber